摘    要:根据丽水地区电网谐波治理的实践,分析谐波产生的原因和危害,进行谐波治理方案的比较,讨论适合丽水地区电网的谐波治理方案。谐波治理主要有电网集中治理模式、特殊变压器就地治理模式及无源滤波装置就地治理模式,其中无源滤波模式较为成熟,值得推广。

关 键 词:谐波污染  谐波治理  无源滤波装置
文章编号:1009-1831(2006)02-0053-02
收稿时间:2005-08-01
修稿时间:2005-11-04

Status and eliminating strategy for harmonic pollution in Lishui district
YU Zhao-zhong. Status and eliminating strategy for harmonic pollution in Lishui district[J]. Power Demand Side Management, 2006, 8(2): 53-54
Authors:YU Zhao-zhong
Affiliation:Lishui Power Supply Company,Lishui 323000, China
Abstract:Based on the harmonic eliminating practice in Lishui district, this paper analyzes the reasons and hazards of harmonic, compares different harmonic eliminating plans, and discusses plans suitable for power system in Lishui district. These modes include centralized elimination,special transformer on the spot and passive filter on the spot. The passive filter mode is mature and deserves to popularize.
Keywords:harmonic pollution  harmonic elimination  passive filter