Highly efficient dual-channel cytometric-detection of micron-sized particles in microfluidic device
Authors:Canjun MuAuthor VitaeFeiling ZhangAuthor Vitae  Zhiyi ZhangAuthor Vitae  Min LinAuthor VitaeXudong CaoAuthor Vitae
Affiliation:a Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario, Canada K1N 6N5
b Institute for Microstructural Sciences, National Research Council Canada, Ottawa, Ontario, Canada K1A 0R6
c Canadian Food Inspection Agency, Ottawa, Ontario, Canada K2H 8P9
Abstract:To demonstrate the ability to efficiently count and identify suspended micron-sized particles by simultaneously detecting their fluorescence emission and light scattering in microfabricated channel, a compact configuration that used a polydimethylsiloxane (PDMS) microfabricated channel as interrogation component, hydrodynamic focusing for particle control, and a simple free-space optical setup for signal detection, was accordingly developed. Subsequently, a quantitative count of 1.013 μm diameter fluorescently labeled beads in suspension was implemented in a microfluidic device employing both fluorescence emission and light scattering at average particle throughput ranging from 83 to 416 particles/s. As a result, the detection efficiencies above 88% for both signals and correlation percentages above 97% between them were routinely achieved. In addition, it was shown that effective differentiation of 1.013 μm fluorescently labeled beads from various unlabeled beads in mixed populations of high mixing ratios had been successfully realized in this microfluidic-device-based instrumentation. Finally, the demonstrated system was used to detect fluorescein isothiocyanate (FITC) labeled nonpathogenic bacteria of Escherichia coli (E. coli) DH5α. The results showed the detection efficiencies above 89.7% for fluorescence emission and 94.5% for light scattering signals, and a correlation of 94.9% between the two signals at an average throughput of 350 cells/s have been obtained. As a comparison, the detection accuracies of the dual-channel cytometric detection of the FITC-labeled E. coli DH5α cells in the microfluidic device are approximately 84.3% and 88.8% for fluorescence emission and light scattering respectively when compared against a manual cell count using a haemocytometer as a standard.
Keywords:Microfabricated channel  Cytometric analysis  Dual channel detection  High throughput measurement
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号