首页 | 本学科首页   官方微博 | 高级检索  
     

用氧化塘—浮石床湿地系统处理暖寒季低污染河水
引用本文:莫文锐,虢清伟,黄建洪,田森林,许振成.用氧化塘—浮石床湿地系统处理暖寒季低污染河水[J].水资源与水工程学报,2012,23(1):69-72.
作者姓名:莫文锐  虢清伟  黄建洪  田森林  许振成
作者单位:1. 环境保护部华南环境科学研究所,广东广州510655;昆明理工大学环境科学与工程学院,云南昆明650500
2. 环境保护部华南环境科学研究所,广东广州,510655
3. 昆明理工大学环境科学与工程学院,云南昆明,650500
基金项目:国家水体污染控制与治理科技重大专项(2009ZX07102-003-4)
摘    要:在滇池流域构建氧化塘-浮石床湿地复合系统对暖季与寒季的城市低污染河水开展了净化效能研究。结果表明:该系统可通过小幅调节流量来有效净化暖季与寒季低污染河水。塘与湿地的水力负荷分别为0.22、0.37m3/(m2.d)时系统对暖季低污染河水具有较高的处理效率,各污染物的平均去除率分别为CODCr75%、TP 93%、TN 64%、NH4+-N 87%。塘与湿地的水力负荷分别为0.17、0.29 m3/(m2.d)时系统对寒季低污染河水具有较优的处理效果:各污染物的平均去除率分别为CODCr72%、TP 89%、TN 53%、NH4+-N 73%。系统出水均符合GB18918-2002的一级A排放标准。系统在暖季对低污染河水中污染物的去除速率明显高于寒季。

关 键 词:氧化塘  浮石  人工湿地  低污染河水
收稿时间:2011/9/10 0:00:00
修稿时间:2011/12/13 0:00:00

Treatment of slightly polluted river water by the combinedsystem of oxidation pond with constructed wetland using pumice as substrate in warm and cold seasons
MO Wenrui,GUO Qingwei,HUANG Jianhong,TIAN Senlin and XU Zhencheng.Treatment of slightly polluted river water by the combinedsystem of oxidation pond with constructed wetland using pumice as substrate in warm and cold seasons[J].Journal of water resources and water engineering,2012,23(1):69-72.
Authors:MO Wenrui  GUO Qingwei  HUANG Jianhong  TIAN Senlin and XU Zhencheng
Affiliation:1(1.South China Institute of Environmental Sciences,MEP,Guangzhou 510655,China; 2.Faculty of Environmental Science and Engineering,Kunming University of Science and Technology,Kunming 650500,China)
Abstract:An study on treatment of slightly polluted river water was carried out using the combined system of oxidation pond with constructed wetland using pumice as substrate in Kunming.The results shown that the system can purify polluted river water both in warm and cold seasons efficiently by regulating flow to a small extent.When the hydraulic loading rates of pond and wetland were held at 0.22 and 0.37 m3/(m2· d) respectively,adequate treatment could be got by the whole combined system and the mean removal efficiencies of CODCr,TP,TN and NH4 +-N in the system for warm season were 75%,93%,64%,87% respectively,and for cold season were CODCr 72%,TP 89%,TN 53%,NH4 +-N 73% at the appropriate hydraulic loading rates of pond and wetland held at 0.17 and 0.29 m3/(m2· d) respectively.The treated water met the standard A of grade I discharge standard of pollutants for municipal waste water treatment plant,and can be used as urban general reuse water.Contaminant removal rate in the combined system in warm season was apparently higher than that in bcold season.
Keywords:oxidation pond  pumice  constructed wetland  slightly polluted river water
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《水资源与水工程学报》浏览原始摘要信息
点击此处可从《水资源与水工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏