首页 | 本学科首页   官方微博 | 高级检索  
     

双喷嘴挡板伺服阀前置放大器的流场分析
引用本文:郭威,杨洁明,任锡义,霍鹏飞.双喷嘴挡板伺服阀前置放大器的流场分析[J].流体传动与控制,2010(2):28-30.
作者姓名:郭威  杨洁明  任锡义  霍鹏飞
作者单位:太原理工大学机械电子工程研究所,山西太原,030024
摘    要:运用FLUENT软件对伺服阀双喷嘴挡板级进行了三维流场分析,获得了不同喷嘴挡板距的控制压力和恢复流量,运用二次函数拟合得到控制压力与恢复流量的数学模型,并分析了喷嘴挡板内部流道对伺服阀性能的影响。

关 键 词:双喷嘴挡板伺服阀  前置放大器  流场分析  FLUENT

Nozzle Flapper Servo Valve Pilot Stage Flow Analysis
Guo Wei,Yang Jieming,Ren xiyi,Huo Pengfei.Nozzle Flapper Servo Valve Pilot Stage Flow Analysis[J].Fluid Power Transmission & Control,2010(2):28-30.
Authors:Guo Wei  Yang Jieming  Ren xiyi  Huo Pengfei
Affiliation:Guo Wei Yang Jieming Ren xiyi Huo Pengfei
Abstract:The three-dimensional flow field of the twin flapper-nozzle servo-valve is analyzed by using FLUENT software, the controlled pressure and recovery flow rate in twin flapper-nozzle amplifier are obtained under different flapper-nozzle distance. The mathematical model of controlled pressure and recovery flow rate is established by function fit method. And the effect of twin flapper-nozzle's internal flow on the characteristic of servo-valve is analyzed. This study provides some reference to the design of twin flapper-nozzle servo valve to a certain extent.
Keywords:FLUENT twin flapper-nozzle servo valve internal flow analysis  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号