首页 | 本学科首页   官方微博 | 高级检索  
     

ICP-MS测定粉煤灰中微量铀的不确定度评定
引用本文:杨丹丹,郭国龙,王春叶,丁红芳. ICP-MS测定粉煤灰中微量铀的不确定度评定[J]. 铀矿冶, 2019, 0(3): 195-197
作者姓名:杨丹丹  郭国龙  王春叶  丁红芳
作者单位:核工业北京化工冶金研究院
摘    要:建立了电感耦合等离子体质谱法(ICP-MS)测定粉煤灰中微量铀的分析方法。对测定过程中不确定度来源进行分析,合成了扩展不确定度。结果表明重复性引入的不确定度和铀标准溶液配制引入的不确定度是测定粉煤灰中铀的主要影响因素。

关 键 词:ICP-MS  粉煤灰  微量铀  不确定度

Evaluation of Uncertainty for Determination of Trace Uranium in Coal Fly Ashes by ICP-MS
YANG Dan-dan,GUO Guo-long,WANG Chun-ye,DING Hong-fang. Evaluation of Uncertainty for Determination of Trace Uranium in Coal Fly Ashes by ICP-MS[J]. Uranium Mining and Metallurgy, 2019, 0(3): 195-197
Authors:YANG Dan-dan  GUO Guo-long  WANG Chun-ye  DING Hong-fang
Affiliation:(Beijing Research Institute of Chemical Engineering and Metallurgy,CNNC,Beijing 101149,China)
Abstract:The method of determination of trace uranium in coal fly ashes was established by inductively coupled plasma mass spectrometry(ICP-MS). The sources of the uncertainty were analysed in process of determination. The expanded uncertainty was synthetized. The results show that repeatability and standard uranium solution preparation were two major factors which influence the uncertainty in the uranium analysis process.
Keywords:ICP-MS  coal fly ashes  trace uranium  uncertainty