首页 | 本学科首页   官方微博 | 高级检索  
     

20碳钢在三元复合驱溶液中的腐蚀行为
引用本文:王为,项民.20碳钢在三元复合驱溶液中的腐蚀行为[J].中国腐蚀与防护学报,1998,18(3):203-208.
作者姓名:王为  项民
作者单位:[1]天津大学应用化学系 [2]郑州轻工业学院化工系
摘    要:采用电化学测试技术与XPS技术,研究了20碳钢在三元复合驱溶液中的的电化学行为及钝化膜的组成与结构,结果表明,20碳钢在三元复合驱溶液中发生钝化,形成的钝化膜组成为:Fe3O4,FeOOH,Fe2O3和Fe(OH)2,其厚度约为7nm铁元素价态沿钝化膜深度变化,由表面+3价到近基体表面+3价与+2价并存。

关 键 词:碳钢  三元复合驱溶液  钝化膜  XPS  腐蚀  采油

CORROSION BEHAVIOUR OF MILD STEEL IN TRIAXIAL COMPOSITE FLOODING SOLUTION
WANG Wei GUO He-tong GAO Jian-ping.CORROSION BEHAVIOUR OF MILD STEEL IN TRIAXIAL COMPOSITE FLOODING SOLUTION[J].Journal of Chinese Society For Corrosion and Protection,1998,18(3):203-208.
Authors:WANG Wei GUO He-tong GAO Jian-ping
Abstract:Mild steel (0.24wt% C) can be passivated in triaxial composite flooding solution containing 1.2% NaCl 0.6% petroleum sulfonate 0.12% polyacrylamide(wt%). The composition and structure of passive film formed on the steel were investigated by XPS. The results showed that the passive film was composed of Fe3O4, FeOOH, Fe2O3 and Fe(OH)2, and its thickness was about 7nm. The valence of elemental iron varied at different depth of the passive film. At the outer surface of the passive film, the valence of iron was 3, and at the interface near the matrix, 3 and 2 iron were detected.
Keywords:Mild steel  Triaxial composite flooding solution  Passive film  XPS
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号