摘    要:该文通过对中性点接地方式的比较和运行情况的分析(包括供电可靠性、安全性等),对中压电网的中性点消弧线圈接地方式及小电阻接地方式进行了探讨。对小电阻接地方式改造提出了具体建议。

关 键 词:中压系统  中性点  消弧线圈  小电阻  零序保护

Research on Neutral Point Grounding Mode of Intermediate Voltage Power System
XING Cai-juan,DU Xue-Long. Research on Neutral Point Grounding Mode of Intermediate Voltage Power System[J]. Metallurgical Equipment Management and Maintenance, 2012, 0(6): 67-68,70
Authors:XING Cai-juan  DU Xue-Long
Affiliation:(Power Plant of Tangshan Iron & Steel Co., Ltd., Tangshan 063016)
Abstract:By comparing the neutral point grounding mode and analyzing its operation states (including the reliability and safety of power supply), make a discussion on the neutral point grounding mode with arc suppression coil and the small resistance grounding mode, and put forward some specific proposals for the modification of the small resistance grounding mode.
Keywords:Intermediate voltage system   neutral point   arc suppression coil   small resistance  zero sequence protection