摘    要:提出了一种在区域供冷系统的换热间用混水器替代板式换热器的方案.该方案具有造价低、施工简单、换热效率高的优点,可应用于区域供冷或供热系统的工程实践中.

关 键 词:区域供冷  混水器  板式换热器

Engineering Example of Using Water Mixer Instead of Plate Heat Exchangerin District Cooling System
WEI Guohua , WU Shusheng. Engineering Example of Using Water Mixer Instead of Plate Heat Exchangerin District Cooling System[J]. Refrigeration, 2012, 31(2): 77-79
Authors:WEI Guohua    WU Shusheng
Affiliation:(Guangzhou University City Energy Development Co.,Ltd.,Guangzhou 510006)
Abstract:One solution using water mixer to replace plate heat exchanger in district cooling system is proposed.And the practice show that the solution has such advantages as low cost,simply making and high eat exchange efficiency etc.with the same effect.And it can be used in district cooling or heating systems.
Keywords:District cooling  Water mixer  Plate heat exchanger