首页 | 本学科首页   官方微博 | 高级检索  
     

文昌13-1/2油田液化石油气铜腐超标治理方法的研究及应用
引用本文:张保山,冯宇.文昌13-1/2油田液化石油气铜腐超标治理方法的研究及应用[J].化工进展,2015,34(Z1):207-211.
作者姓名:张保山  冯宇
作者单位:1. 中海石油(中国)有限公司湛江分公司文昌作业公司, 广东 湛江 524057; 2. 天津亿利科能源科技发展股份有限公司, 天津 300384
摘    要:文昌13-1/2油田液化石油气(LPG)回收项目是中海石油(中国)有限公司湛江分公司首个海上LPG回收项目。近年来文昌油田LPG产品时而会发生铜腐测试不合格情况,本文通过对LPG系统硫化氢检测,LPG气样总硫含量测试以及铜片腐蚀产物的能谱测试,发现文昌油田LPG气样铜腐超标和硫含量超标有关。根据海上油田生产环境特点,拟采取湿法脱硫技术,直接加注脱硫剂的方法治理铜腐不合格问题。现场试验加药点选在进口压缩机进口,这样既可以给脱硫剂与硫化氢反应提供空间和时间,又可以在LPG系统较前端将硫化氢治理到较低水平,防止了硫化氢在LPG系统中的扩散。液化气脱硫剂以加注量50mL/min,在现场实践应用的一个月的时间里,可以有效地将铜腐指标从2a降低到1a,确保LPG产品符合国标标准要求。

关 键 词:液化石油气  腐蚀  脱硫剂  反应  生产  

Research and application of the method of controling copper corrosion for Wen13-1/2 oilfield liquefied petroleum gas (LPG)
ZHANG Baoshan,FENG Yu.Research and application of the method of controling copper corrosion for Wen13-1/2 oilfield liquefied petroleum gas (LPG)[J].Chemical Industry and Engineering Progress,2015,34(Z1):207-211.
Authors:ZHANG Baoshan  FENG Yu
Affiliation:1. CNOOC Wenchang Oilfield Operation District Co., Ltd., ‘Zhanjiang branch’, Zhanjiang 524057, Guangdong, China;
2. E-Tech.Energy Technology Development Co., Ltd., Tianjin 300384, China
Abstract:Wen13-1/2 oil field liquefied petroleum gas (LPG) recycling project is the first offshore LPG recycling project in CNOOC (China) Co., Ltd.Zhanjiang branch.In recent years,LPG gas copper corrosion exceeding occurs sometimes.By detecting hydrogen sulfide, total sulfur content of LPG gas sample and testing copper corrosion product through energy spectrum test, Wen13-1/2 oil field LPG copper corrosion exceeding is concerned with sulfur content exceeding.According to the characteristics of production conditions in offshore oil field, we propose to adopt wet desulfuring technologies--direct injection of hydrogen sulfide scavenger to solve unqualified copper corrosion problems.Field test injection point is set on compressor entrance, which can provide space and time for reaction between the hydrogen sulfide scavenger with hydrogen sulfide and can also manage hydrogen sulfide to lower levels from upstream of LPG systems, preventing the proliferation of hydrogen sulfide in the LPG system.Liquefied petroleum gas desulfurizer goes with filling volume 50mL/min.During a month's time of field test, copper corrosion index can be effectively decreased to 1a from 2a,which can ensure that LPG products comply with national standard.
Keywords:LPG  corrosion  hydrogen sulfide scavenger  reaction  production  