摘    要:分析了300 MW机组事故停机后机组无辅汽等外来汽源的孤立方式热态启动过程。该热态启动过程能够保证机组参数均在允许控制范围。此次特殊方式热态启动成功,为其它同类电厂黑启动时无启动炉供辅汽方式提供实践依据。

关 键 词:热态启动  偏心  轴封  辅汽

Analysis of solitary hot start without auxiliary steam of 300 MW unit
ZHANG Xuejun.Analysis of solitary hot start without auxiliary steam of 300 MW unit[J].Heilongjiang Electric Power,2010,32(5):370-372,376.
Authors:ZHANG Xuejun
Affiliation:ZHANG Xuejun(Sanhe Power Generation Company,Sanhe 065201,China)
Abstract:This paper analyzes the solitary hot start without auxiliary steam after emergency outage,discovering the 300 MW unit parameters are all within acceptable control rage,and expounds critical control point during hot start.This special hot start offers reference to other same kind of power plants' black start without start-up furnace supplying auxiliary steam.
Keywords:hot start  eccentricity  shaft seal  auxiliary steam