Uncertainty assessment of a prototype of multilateration coordinate measurement system
Affiliation:1. Department of Engineering Physics, Ankara University, Tando?an, Ankara 06100, Turkey;2. European XFEL, Albert-Einstein-Ring 19, Hamburg 22761, Germany;3. Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany;1. Laboratory for Machine Tools and Production Engineering (WZL) of RWTH Aachen University, Germany;2. National Physical Laboratory, TW11 0LW, United Kingdom;1. Department of Micro Engineering, Kyoto University, Nishikyo-ku, Kyoto 615-8530, Japan;2. Institute of Machine Tools and Manufacturing (IWF), ETH Zurich, Technoparkstrasse 1, PFA E81, 8005 Zurich, Switzerland;3. DMG Mori, Co., Ltd., Meieki 2-35-16, Nakamura-ku, Nagoya 450-0002, Japan;1. LNE, 1 rue Gaston Boissier, 75724 Paris cedex 15, France;2. LURPA, ENS de Cachan, Univ. Paris-Sud, Université Paris-Saclay, 94235 Cachan, France
Abstract:Large Volume Metrology is essential to many high value industries to go towards the factory of the future, but also to many science facilities for fine alignment of large structures. In this context, we have developed a multilateration coordinate measurement system, traceable to SI metre, and suitable for outdoor measurements or industrial environments. It is based on a high accuracy absolute distance meter developed in-house and shared between several measurement heads by fibre-optic links. Thus, from these measurement stations, multiple distance measurements of several positions of a target can be performed. At the end, coordinates of the heads and of the different target locations are determined using a multilateration algorithm with self-calibration.In this paper, the uncertainty of this multilateration coordinate measurement system is determined with a consistent metrological approach. First, 13 different sources of errors are listed and quantified. Then, thanks to Monte Carlo simulations, the standard uncertainty on a single absolute distance measurement is assessed to 4.7 μm. This includes the uncertainty contribution of the telemetric system itself, but also the contributions of the mechanical designs of the measurement heads and the target. Lastly, measurements of three-dimensional coordinates of target positions are performed in a control environment, then in a large workshop without temperature control: these measurements validate the uncertainty assessment of the system.
Keywords:Dimensional metrology  Large volume metrology  Absolute distance metre  Coordinate measurement system  Multilateration technique with self-calibration
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号