首页 | 本学科首页   官方微博 | 高级检索  
     


Spatially resolved degradation in heterophasic polymers by ESR imaging and FTIR: The case of propylene-ethylene copolymers
Authors:Email author" target="_blank">Shulamith?SchlickEmail author  Kryzstof?Kruczala
Affiliation:(1) Department of Chemistry and Biochemistry, University of Detroit Mercy, 48219-0900 Detroit, MI;(2) Faculty of Chemistry, Jagiellonian University, 30-060 Krakow, Poland
Abstract:Heterophasic propylene-ethylene copolymers (HPEC) containing bis(2,2,6,6-tetramethyl-4-piperidinyl) sebacate (Tinuvin 770) as a hindered amine stabilizer (HAS) were thermally aged at 393 and 433 K. Two types of HPEC were examined, containing 25% and 10% ethylene (E), respectively, as ethylene/propylene rubber (EPR). Electron spin resonance (ESR) spectra of nitroxide radicals in HPEC were studied in the temperature range 100–433 K; the nitroxides were derived from the HAS and are termed HAS-NO. The results were compared with ESR spectra of the same radicals obtained first by oxidation of Tinuvin 770 and then were doped in HPEC and related homopolymers, polyethylene (PE) and polypropylene (PP); these nitroxides are termed “spin probes.” ESR spectra indicated that HAS-NO and the spin probes reside in a range of amorphous sites differing in their dynamic properties. The relative population of the sites was explained by assuming that the crystalline domains exert a restraining effect on chains located in vicinal amorphous domains. Spatial and temporal effects of the aging process were studied by ESR and ESR imaging (ESRI) of HAS-derived nitroxide radicals, and by FTIR of films prepared by compression molding. 1D ESRI enabled the visualization of an outer region of thickness ≈100 μm that contained a lower amount of nitroxides, and is believed to result from the loss of the stabilizer by diffusion (“blooming”) and possibly also in chemical reactions during aging. Two-dimensional spectral-spatial ESRI indicated the presence of nitroxide radicals in two amorphous sites, fast and slow; the corresponding relative intensity varied with sample depth. Both ESRI and FTIR experiments suggested a faster degradation rate in HPEC containing 25% E, as compared to 10% E; moreover, a larger Tinuvin 770 content in the polymers led to less efficient stabilization. FTIR spectra indicated increased ordering of polypropylene segments in HPEC during aging at 433 K.
Keywords:Hindered amine stabilizer  FTIR  ATR  non-destructive testing  thermal analysis  ESR and ESR imaging  stablization  thermal properties  thermoplastic olefins
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号