摘    要:针对水轮发电机转子动态接地故障的特点,从制造、检修安装、运行等方面进行了分析,通过对保护装置、外围设备、磁极等进行反复检查、试验,提出建设性的空转测量方法,找出故障点,彻底处理故障,这种特殊的转子接地故障处理经验具有现实指导意义.

关 键 词:水轮发电机转子  动态接地  处理
文章编号:1000-3983(2007)02-0015-02
修稿时间:2006-05-15

Analysis and Treatment for Dynamic Grounding Fault of Hydrogenerator Rotor
LI Fu-ying. Analysis and Treatment for Dynamic Grounding Fault of Hydrogenerator Rotor[J]. Large Electric Machine and Hydraulic Turbine, 2007, 0(2): 15-16,31
Authors:LI Fu-ying
Affiliation:Guangdong Yudean Xinfengjiang Power Gemeration Co., Ltd, Heyuan 517021,China
Abstract:In view of hydrogenerator rotor dynamic grounding fault characteristics,analysis is carried out from aspects of manufacture,overhaul installment,operation and so on.Through repeated examinations and tests,constructive proposals for the measurement of no-load operation is given,to find out the fault location and eliminate the fault thoroughly.This special experience of rotor ground fault treatment is of great practical significance.