首页 | 本学科首页   官方微博 | 高级检索  
     

内压球壳大开孔接管区电阻应变测量中不确定度的评定
引用本文:杜雅飞,高炳军,张及瑞. 内压球壳大开孔接管区电阻应变测量中不确定度的评定[J]. 中国测试技术, 2004, 30(5): 23-25
作者姓名:杜雅飞  高炳军  张及瑞
作者单位:河北工业大学化工学院,天津,300130
摘    要:本文对内压球壳大开孔接管区电阻应变测量进行了测量不确定度的B类评定 ,发现其外壁应力测量相对标准不确定度一般不超过 2 % ,可满足实验应力分析要求

关 键 词:测量不确定度  电阻应变测量
文章编号:1672-4984(2004)05-0023-03
修稿时间:2003-12-08

Evaluation of strain gauge measurement uncertainty in the connecting region of spherical shell with large opening nozzle
DU Ya-fei,GAO Bing-jun,ZHANG Ji-rui. Evaluation of strain gauge measurement uncertainty in the connecting region of spherical shell with large opening nozzle[J]. China Measurement Technology, 2004, 30(5): 23-25
Authors:DU Ya-fei  GAO Bing-jun  ZHANG Ji-rui
Abstract:B-type measurement uncertainty evaluation was made for the strain measurement by gauges in the connecting region of spherical shell with large opening nozzle.It was found that the standard measurement uncertainty is generally less than 2% for the outside wall strain measurement,which can meet the need of stress experimental analysis.
Keywords:Measurement uncertainty  Strain gauge measurement
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号