Adaptive Chirp Transform for frequency measurement |
| |
Authors: | Petar Mostarac Roman Malari?Hrvoje Hegeduš |
| |
Affiliation: | Faculty of Electrical Engineering and Computing, University of Zagreb, Unska 3, 10000 Zagreb, Croatia |
| |
Abstract: | In this paper Adaptive Chirp Transform (ACT) algorithm for power frequency measurement is presented. It is adjusted for continuous monitoring of power frequency. Signal is first preprocessed with adaptive filter to minimize the error of non-linear model parameters. The resulting parameters are used to narrow the frequency range for CZT method to be effective. Algorithm code has been analyzed and computation complexity has been significantly decreased. Using this algorithm it is possible to measure frequency transients with sufficient accuracy and low execution time. Algorithm is verified through simulations and real-time data. |
| |
Keywords: | Chirp-z transform Frequency measurement Interpolated discrete Fourier transform |
本文献已被 ScienceDirect 等数据库收录! |