首页 | 本学科首页   官方微博 | 高级检索  
     


A Josephson voltage-traceable DC high-voltage divider evaluation using the binary step-up method
Authors:Sang Hwa LeeKwang Min Yu  Jeon Hong KangMun Seog Kim  Kyu Tae Kim
Affiliation:Korea Research Institute of Standards and Science (KRISS), 1 Doryong-Dong, Yuseong-Gu, Daejeon 305-340, Republic of Korea
Abstract:An evaluation technique and traceability for a DC-resistive high-voltage divider was established based on 1 kV, which was traceable to a Josephson voltage standard at the Korea Research Institute of Standards and Science. To do this, the binary step-up method was used to evaluate the voltage-dividing ratio and the voltage coefficient of the divider up to 100 kV. The expanded relative uncertainty for the dividing ratio up to 100 kV was 16 × 10−6 level. To confirm the validity of the method, the ratio at 1 kV was compared with the resistance ratio of the divider, and the two results agreed to within 5.3 × 10−6.
Keywords:Josephson voltage standard  Binary step-up  DC high-voltage ratio  DC-resistive high-voltage divider  Voltage coefficient
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号