A Josephson voltage-traceable DC high-voltage divider evaluation using the binary step-up method |
| |
Authors: | Sang Hwa LeeKwang Min Yu Jeon Hong KangMun Seog Kim Kyu Tae Kim |
| |
Affiliation: | Korea Research Institute of Standards and Science (KRISS), 1 Doryong-Dong, Yuseong-Gu, Daejeon 305-340, Republic of Korea |
| |
Abstract: | An evaluation technique and traceability for a DC-resistive high-voltage divider was established based on 1 kV, which was traceable to a Josephson voltage standard at the Korea Research Institute of Standards and Science. To do this, the binary step-up method was used to evaluate the voltage-dividing ratio and the voltage coefficient of the divider up to 100 kV. The expanded relative uncertainty for the dividing ratio up to 100 kV was 16 × 10−6 level. To confirm the validity of the method, the ratio at 1 kV was compared with the resistance ratio of the divider, and the two results agreed to within 5.3 × 10−6. |
| |
Keywords: | Josephson voltage standard Binary step-up DC high-voltage ratio DC-resistive high-voltage divider Voltage coefficient |
本文献已被 ScienceDirect 等数据库收录! |