摘    要:分析了龙湾燃机电厂220kVSF6断路器爆炸的原因(如制造工艺等)及其过程;介绍了断路器爆炸的处理及防范措施(如应缩短燃机电厂主变压器的检测周期,加强对灭弧室顶盖处金属连接部件的红外测温等)。

关 键 词:断路器  爆炸  分析  燃气轮机  主变压器
收稿时间:2005-09-30
修稿时间:2005年9月30日

Reasons and Measures for Preventing Explosion of 220 kV SF6 Circuit Breaker
PAN Xia-qing.Reasons and Measures for Preventing Explosion of 220 kV SF6 Circuit Breaker[J].Electrical Equipment,2006,7(6):63-65.
Authors:PAN Xia-qing
Abstract:The explosion reasons of 220 kV SF_6 circuit breaker and its process in Longwan Gas Turbine Power Plant were analyzed. The handling of the explosive circuit breaker and its preventive measures were introduced, such as reducing the detection period of the main transformer for gas turbine power plant, strengthening infrared temperature monitoring for metal connection parts in top cover of arc extinguish room.
Keywords:circuit breaker  explosion  analysis  gas turbine  main transformer