首页 | 本学科首页   官方微博 | 高级检索  
     

基于修改后RELAP5/MOD3.2的氟盐高温堆实验回路分析
引用本文:许荣栓,刘利民,王宁,张大林,王成龙,秋穗正,苏光辉.基于修改后RELAP5/MOD3.2的氟盐高温堆实验回路分析[J].原子能科学技术,2017,51(5):828-835.
作者姓名:许荣栓  刘利民  王宁  张大林  王成龙  秋穗正  苏光辉
作者单位:1.西安交通大学 核科学与技术学院,陕西 西安710049;2.中国核动力研究设计院,四川 成都610213
基金项目:国家自然科学基金资助项目(91326201
摘    要:大型热工流体整体效应系统实验(CIET)台架是为模拟氟盐冷却高温堆(FHR)热工水力响应而设计的实验回路,采用DOWTHERM A模拟氟盐作为冷却剂。通过在RELAP5/MOD3.2程序中加入DOWTHERM A物性参数以及传热关系式,计算FHR实验回路CIET在两种工况下的热工水力行为,并与实验结果进行对比,计算工况包括强迫循环条件与自然循环条件。计算结果表明:在强迫循环条件下,堆芯热量主要靠盘管式空气换热器(CTAH)排出,堆芯进出口冷却剂温度及CTAH出口冷却剂温度与实验值符合良好,CTAH进口冷却剂温度与实验值有些微偏差;在自然循环工况中,堆芯热量主要通过DHX与堆芯辅助冷却系统(DRACS)回路的换热带走,DHX及DRACS的流量与实验值接近,相对误差在10%左右,验证了修正后RELAP5/MOD3.2的正确性。

关 键 词:氟盐冷却高温堆    CIET    RELAP5/MOD3.2

Transient Analysis of Fluoride-salt-cooled High-temperature Reactor Test Facility Based on Modified RELAP5/MOD3.2
XU Rong-shuan,LIU Li-min,WANG Ning,ZHANG Da-lin,WANG Cheng-long,QIU Sui-zheng,SU Guang-hui.Transient Analysis of Fluoride-salt-cooled High-temperature Reactor Test Facility Based on Modified RELAP5/MOD3.2[J].Atomic Energy Science and Technology,2017,51(5):828-835.
Authors:XU Rong-shuan  LIU Li-min  WANG Ning  ZHANG Da-lin  WANG Cheng-long  QIU Sui-zheng  SU Guang-hui
Affiliation:1.School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China;2.Nuclear Power Institute of China, Chengdu 610213, China
Abstract:The compact integral effects test (CIET) facility was designed to investigate the thermal hydraulic responses of fluoride-salt-cooled high-temperature reactor.CIET facility uses DOWTHERM A fluid to simulate fluoride salt.Thermo-physical properties and transport of DOWTHERM A were implemented into the RELAP5/MOD3.2.The modified RELAP5 code was adopted to study thermal hydraulic behavior of DOWTHERM A under forced circulation operation and natural circulation operation of CIET facility respectiv-ely.Calculation results of core inlet and outlet temperatures and the coiled tube air heater outlet temperature are in good agreement with the corresponding experimental data under forced circulation operation.The inlet temperatures of coiled tube air heater are slightly different from the experiment data.In natural circulation the computational results indicate that the decay heat is mainly removed through the DRACS.The computational flow rates of DHX and DRACS are close to the experiment data.Furthermore, the relative error of flow rate between calculation results and experiment data is about 10%.The results prove the accuracy of the modified RELAP5/MOD3.2.
Keywords:fluoride-salt-cooled high-temperature reactor  compact integral effects test  RELAP5/MOD3  2
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号