An analytical method to calculate temperatures of components of reverse channel connection to concrete filled steel section under fire conditions
Affiliation:1. College of Civil Engineering, Tongji University, Shanghai 200092, China;2. School of Mechatronic Engineering, Southwest Petroleum University, Chengdu 610500, China;3. Shanghai Tonglei Civil Engineering Technology Co. Ltd., Shanghai 200092, China
Abstract:The paper describes the development of an analytical model for calculating the temperatures of different components of reverse channel connections to concrete filled steel tubular sections. The proposed analytical model is based on the Lumped Capacitance Method and includes the calculation of the quantity of heat transferred at the interface between the steel tube and the concrete core. For unprotected connections, the connection is divided into two regions. One part of the connection is almost unaffected by the presence of the concrete core, on the contrary, temperature of the second part of the connection is significantly affected by the heat transfer at the steel/concrete interface. For protected connections, the entire connection is assumed to have the same temperature. Equivalent two-dimensional section factors are proposed for these connection parts. The analytical model is developed based on the results of extensive parametric studies under standard and different parametric fire conditions and validated against fire test results. The proposed analytical method is applicable to both fire protected and unprotected connections, including both the heating and cooling periods of the fire attack, and incorporating the effects of in-fill concrete.
Keywords:Reverse channel connection  Fire protected connection  Concrete filled tube  Heat transfer  Temperature calculation  Analytical model  Lumped Capacitance Method  Heat flux density  Section factor
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号