Reactivity balance in the IPR-R1 TRIGA reactor
Authors:Rose Mary Gomes do Prado Souza  Amir Zacarias Mesquita
Affiliation:Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Av. Presidente Antônio Carlos, 6627, Campus UFMG, Pampulha, 31.270-901 Belo Horizonte, MG, Brazil
Abstract:Considering that the power of the IPR-R1 TRIGA reactor, located at the Nuclear Technology Development Center, Brazil, will be increased from 100 kW to 250 kW, some experiments were done in order to evaluate the magnitude of the reactivity effects associated with the reactor operation. The core excess of reactivity obtained was 1.99 $, and the shutdown margin was 1.33 $. The reactivity needed to operate the IPR-R1 reactor at 100 kW was 0.72 $, mainly due to the prompt negative temperature coefficient. A significant amount of reactivity is needed to overcome temperature and allow the reactor to operate at the higher power levels. The loss of reactivity due to xenon poisoning after 8 h of operation at 100 kW was around 0.20 $, and the highest reactivity loss value caused by a void inserted in the central thimble was 0.22 $. From the results obtained, it was possible to balance all the determined reactivity losses with the reactivity excess available in the reactor, considering the present and the future reactor power operation.
Keywords:TRIGA research reactor   Control rods worth   Reactivity   Xenon poisoning   Void