首页 | 本学科首页   官方微博 | 高级检索  
     


Power control of CANDLE reactor by coolant flow rate
Authors:Shinsuke Nakayama  Tsuyoshi OkawaHiroshi Sekimoto
Affiliation:Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1, Ookayama, Meguro-ku, Tokyo 152-8550, Japan
Abstract:CANDLE reactors do not require control rods for burn-up control. Such reactors can achieve the excellent features of previously-considered CANDLE reactors such as constant power shape and reactivity feedback coefficients during the entire operation period at the rated power level. By eliminating control rod use for power level control, the CANDLE reactor can be operated in a load-following mode and its utility will expand dramatically.By numerical calculations, power control by coolant flow rate was studied for the sodium-cooled metallic fuel large CANDLE reactor. The effect of thermal expansion of the core support structure shows considerable contribution toward achieving negative reactivity feedback to improve the power controllability. We employ HT-9 and SUS316 for core support structures. Since the maximum cladding temperature reaches its design constraint, power level cannot be decreased less than its lower limit, which is 66% for HT-9 and 57% for SUS316.
Keywords:CANDLE burn-up   Fast reactor   Reactivity feedback   Power control
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号