首页 | 本学科首页   官方微博 | 高级检索  
     

基于Herriott吸收池的固定源二氧化碳浓度测量研究
引用本文:马路遥,马若梦,祝晓轶,罗永嘉,任歌,林鸿. 基于Herriott吸收池的固定源二氧化碳浓度测量研究[J]. 计量学报, 2022, 43(3): 416-419. DOI: 10.3969/j.issn.1000-1158.2022.03.18
作者姓名:马路遥  马若梦  祝晓轶  罗永嘉  任歌  林鸿
作者单位:1.郑州计量先进技术研究院,河南 郑州 450001
2.中国计量科学研究院,北京 100029
3.郑州高新产业投资集团,河南 郑州 450001
基金项目:国家自然科学基金-青年科学基金(41907272);
摘    要:准确的碳排放计量是实现“碳峰化、碳中和”目标的重要一步。在所有碳排放源中,固定排放源排放的CO2是温室效应的主要因素。因此,精确测量固定排放源CO2的浓度尤为重要。基于近红外分子吸收光谱原理并结合多次反射直接吸收光谱技术,利用35% CO2/N;2混合物,建立了精确测量CO2浓度的方法,测量了293K和0,4.1,8.1,13.3kPa下,CO2在6359.97cm-1的(30012)←(00001)R16e和6361.25cm-1的(30012)←(00001)R18e跃迁谱线,计算了R18e的谱线强度,通过比较35% CO2/N2混合物和其它CO2/N;2混合物的吸收面积,可以得到15%,10%,5%的CO2/N;2混合物的浓度。结果表明所建立的理论方法和实验结果能够较好地表征待测气体的浓度,测量不确定度与基于天平的称重法相当。

关 键 词:计量学  二氧化碳  Herriott吸收池  温室气体  吸收光谱  
收稿时间:2021-11-16

Carbon Dioxide Concentration Measurement of Fixed Source Based on Herriott Absorption Cell
MA Lu-yao,MA Ruo-meng,ZHU Xiao-yi,LUO Yong-jia,REN Ge,LIN Hong. Carbon Dioxide Concentration Measurement of Fixed Source Based on Herriott Absorption Cell[J]. Acta Metrologica Sinica, 2022, 43(3): 416-419. DOI: 10.3969/j.issn.1000-1158.2022.03.18
Authors:MA Lu-yao  MA Ruo-meng  ZHU Xiao-yi  LUO Yong-jia  REN Ge  LIN Hong
Affiliation:1. Zhengzhou Institute of Metrology, Henan, Zhengzhou 450001, China
2. National Institute of Metrology, Beijing 100029, China
3. State High-tech Industry Investment Group, Zhengzhou,Henan 450001, China
Abstract:Accurate carbon emission measurement is an important step to achieve the goal of "carbon peak and carbon neutral". Among all sources of emissions, the emission of carbon dioxide from point sources is a major factor in the greenhouse effect. Therefore, it is important to accurately measure the concentration of carbon dioxide from point sources. Based on the principle of near-infrared molecular absorption spectroscopy combined with multiple reflection direct absorption spectroscopy, an accurate method was established for the measurement of CO2 concentration using 35% CO2/N2mixture.CO2 transitions from (30012)←(00001)R16e of 6359.97cm-1 to (30012)←(00001)R18e of 6361.25cm-1, the spectral line intensity of R18e was calculated.By comparing the absorption areas of 35% CO2/N2mixtures with other CO2/N2 mixtures, concentrations of 15%, 10%, and 5% CO2/N2 mixtures can be obtained. The results show that the theoretical method and experimental results can well characterize the concentration of the gas to be measured, and the uncertainty of measurement is comparable to that of the weighing method based on balance.
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《计量学报》浏览原始摘要信息
点击此处可从《计量学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号