摘    要:高集成电静液作动器(EHA)在减小体积和质量的同时,带来散热能力差、系统油温上升快等问题,导致油液黏度降低而使EHA的流量死区具有时变特性,给EHA的精确控制增加了难度.针对上述问题,考虑油液黏温特性,建立了EHA流量死区的数学模型,分析了流量死区的变化规律,提出了基于系统模型信息的流量死区动态逆补偿方法,对比分析了不...

关 键 词:电静液作动器  流量死区  动态逆补偿方法  黏温特性

Dynamic Inverse Compensation Method of Flow Rate Dead-zone of Electro-hydrostatic Actuator Considering Viscosity-temperature Characteristics of Oil
HAN Xiaoxia,FENG Yongbao,XIE Jian,WEI Liejiang,WANG Yaqiang,WEI Xiaoling. Dynamic Inverse Compensation Method of Flow Rate Dead-zone of Electro-hydrostatic Actuator Considering Viscosity-temperature Characteristics of Oil[J]. Acta Armamentarii, 2022, 43(2): 316-327. DOI: 10.3969/j.issn.1000-1093.2022.02.009
Authors:HAN Xiaoxia  FENG Yongbao  XIE Jian  WEI Liejiang  WANG Yaqiang  WEI Xiaoling
Affiliation:(1.College of Missile Engineering, Rocket Force University of Engineering, Xi'an 710025, Shaanxi, China;2.College of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, Gansu, China;3.China National Heavy Machinery Research Institute Co.,Ltd., Xi'an 710032, Shaanxi, China)
Abstract:The highly integrated electro-hydrostatic actuator (EHA) has been reduced in size and weight, but the poor heat dissipation and rapid increase in system oil temperature have been brought, thus leading to the time-varying characteristics of flow rate dead-zone of EHA resulting from the reduction of oil viscosity. This makes accurate control of EHA more difficult. For the above problems, a mathematical model of EHA flow rate dead-zone is established, in which the viscosity-temperature characteristics of the oil are considered, and the variation law of flow rate dead-zone is analyzed. Furthermore, a dead-zone dynamic inverse compensation method for flow rate based on the system model information is proposed. The compensation effects of proposed method at different speeds and loads are compared and analyzed, and verified through experiment. The results show that the flow rate dead-zone of EHA increases with the rise in temperature, and the proposed dynamic inverse compensation method can compensate the flow rate dead-zone of EHA under light load conditions, which is conducive to improving the control performance of the system.
Keywords:electro-hydrostaticactuator   flowratedead-zone   dynamicinversecompensationmethod   viscosity-temperaturecharacteristics
本文献已被 万方数据 等数据库收录!
点击此处可从《兵工学报》浏览原始摘要信息
点击此处可从《兵工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号