首页 | 本学科首页   官方微博 | 高级检索  
     

高应变率下高温应变计灵敏度系数的校准方法
引用本文:王凡,郭伟国,吴倩,高猛.高应变率下高温应变计灵敏度系数的校准方法[J].兵工学报,2022,43(4):899-909.
作者姓名:王凡  郭伟国  吴倩  高猛
作者单位:(西北工业大学 航空学院, 陕西 西安 710072)
基金项目:国家自然科学基金项目(11872051、12072287);
摘    要:为校准高应变率下高温应变计在高温环境下的灵敏度系数,使用具有快速高温同步组装功能的高温、高应变率耦合的分离式Hopkinson杆装置对其灵敏度系数进行标定.将待校准的高温应变计粘贴在标准试样表面,并与试样处在相同温度与受力环境.对试样同步施加高温与高应变率加载,对比分离式Hopkinson杆上标准应变计信号与试样上高温...

关 键 词:高温应变计  灵敏度  分离式Hopkinson杆  高应变率

Calibration Method for Sensitivity Coefficient of High-temperature Strain Gauges at High Strain Rate
WANG Fan,GUO Weiguo,WU Qian,GAO Meng.Calibration Method for Sensitivity Coefficient of High-temperature Strain Gauges at High Strain Rate[J].Acta Armamentarii,2022,43(4):899-909.
Authors:WANG Fan  GUO Weiguo  WU Qian  GAO Meng
Affiliation:(School of Aeronautics, Northwestern Polytechnical University, Xi'an 710072, Shaanxi, China)
Abstract:A new method is used to calibrate the sensitivity coefficient of the high-temperature strain gauge at high strain rate.The high-temperature strain gauge under calibration is pasted on the surface of a standard specimen by using the split Hopkinson bar with synchronous assembly device,and they are placed in the same temperature and stress environment. The specimen is subjected to impact loading at constant temperature. The sensitivity coefficient of the high-temperature strain gauge is obtained by collecting,calculating and comparing the output signals of the standard strain gauge on the split Hopkinson bar and the high-temperature strain gauge on the specimen. The calibration method applies to calibrate the sensitivity coefficient of guage at the strain rate of 103 s-1 in the temperature range from 293 to 1 473 K. The error of the calibrated sensitivity coefficient caused by the dispersion and attenuation of stress wave have a linear relation with the integral of the amplitude of the incident wave,and the experimental relative error is only 2.39%. The error caused by the inhomogeneous plastic deformation of sample is less than 1.5%,and the uncertainty of calibrated results is 1.517%.The experimental results show that the proposed method can be used to calibrate the sensitivity coefficient of the high-temperature strain gauge at high temperature and high strain rate.
Keywords:high-temperaturestraingauge                                                                                                                        sensitivitycoefficient                                                                                                                        splitHopkinsonbar                                                                                                                        highstrainrate
本文献已被 万方数据 等数据库收录!
点击此处可从《兵工学报》浏览原始摘要信息
点击此处可从《兵工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏