首页 | 本学科首页   官方微博 | 高级检索  
     

刘家峡水电厂1号机转轮更换前后稳定性分析
引用本文:高云涛,刘秀良,王茂元,李金军. 刘家峡水电厂1号机转轮更换前后稳定性分析[J]. 西北水电, 2012, 0(Z1): 198-201
作者姓名:高云涛  刘秀良  王茂元  李金军
作者单位:刘家峡水电厂,甘肃省永靖县,731600
摘    要:阐述了刘家峡水电厂1号机转轮更换前后机组的稳定运行情况,介绍了1号机原转轮叶片裂纹情况、补焊修复措施,并根据转轮更换前后机组稳定性试验数据,分析了机组在不同负荷区域的稳定性能。

关 键 词:转轮  裂纹  稳定性

Analysis on Stability of Unit 1 Runner before and after being Replaced, Liujiaxia Hydropower Plant
GAO Yun-tao , LIU Xiu-liang , WANG Mao-yuan , LI Jin-jun. Analysis on Stability of Unit 1 Runner before and after being Replaced, Liujiaxia Hydropower Plant[J]. Northwest Water Power, 2012, 0(Z1): 198-201
Authors:GAO Yun-tao    LIU Xiu-liang    WANG Mao-yuan    LI Jin-jun
Affiliation:(Liujiaxia Hydropower Plant,Yongjing,Gansu 731600,China)
Abstract:Stability of Unit 1 runner before and after being replaced,Liujiaxia Hydropower Plant is described.Cracks and their welding repair of the original Unit 1 runner blades are introduced.Furthermore,stability performances of units at different loads are analyzed according to test data on stability of units with the runner before and after being replaced.
Keywords:Runner  crack  stability