Helsinki University of Technology, Department of Technical Physics, SF-02150, Espoo, Finland
Abstract:
A comparison between one-year measured and simulated thermal performance of a full-scale seasonal storage solar heating system (CSHPSS) is presented: To minimize simulation inaccuracies, special attention has been paid to the system control and operational strategies. Then the discrepancies on monthly basis are less than 15% and the predicted yearly energy flows differ only by a few percent.