首页 | 本学科首页   官方微博 | 高级检索  
     

600MW发电机组设备事故与维修初探
引用本文:孙国彬. 600MW发电机组设备事故与维修初探[J]. 电机技术, 2012, 0(1): 32-35
作者姓名:孙国彬
作者单位:大唐淮北发电厂 235000
摘    要:电力工业的厂和网分开后,投入运行的大容量、高参数、高自动化机组已陆续运行到A级检修周期。作者对几例600MW机组的频发故障,进行了分析和探讨,就目前这类机组亟待处理的几个技术问题提出建议,以期提高我国600MW机组的制造和运行管理水平。

关 键 词:绝缘监督线圈震动耐压试验短路

Initial Investigation on Equipment Accident of 600MW Generator Sets and Their Maintenance
Sun Guobin. Initial Investigation on Equipment Accident of 600MW Generator Sets and Their Maintenance[J]. Electrical Machinery Technology, 2012, 0(1): 32-35
Authors:Sun Guobin
Affiliation:Sun Guobin Da Tang Huaibei Power Plant
Abstract:The large-capacity,superior performance and fully-automation generator sets invested after the separation between power plants and power network in the power industry had come into the over haul stage of Class A successfully.Combined with the analysis and discussion on several examples of 600 MW generator sets accident,suggestion about how to solve the problems was put forward,so as to increase the manufacturing and operating level of the 600MW generator sets with the engineering technicians in both power industry and equipment manufacturing industry.
Keywords:Supervision on insulation Vibration of coils Voltage understand test Short circuit