火电厂锅炉给水温度耗差分析模型的建立
引用本文:赵志红,丁艳,袁隆基,李聪.火电厂锅炉给水温度耗差分析模型的建立[J].锅炉技术,2011,42(3):24-26.
作者姓名:赵志红  丁艳  袁隆基  李聪
作者单位:中国矿业大学电力工程学院;中国矿业大学徐海学院;
摘    要:分析了锅炉给水温度变化对火电厂机组热经济性的影响,在考虑了给水温度对锅炉效率影响的前提下,建立了锅炉给水温度偏离目标值时的耗差分析模型,利用该模型对某电厂300MW机组运行参数进行耗差计算,其结果可以满足精度要求.

关 键 词:火电厂  给水温度  耗差分析  节能

The Optimization for the Energy-loss Analysis Model of Boiler Feed Temperature in Coal Steam-electric Plant
ZHAO Zhi-hong,DING Yan,YUAN Long-ji,LI Cong.The Optimization for the Energy-loss Analysis Model of Boiler Feed Temperature in Coal Steam-electric Plant[J].Boiler Technology,2011,42(3):24-26.
Authors:ZHAO Zhi-hong  DING Yan  YUAN Long-ji  LI Cong
Affiliation:ZHAO Zhi-hong1,DING Yan2,YUAN Long-ji1,LI Cong1 1.College of Electronic Engineering,China University of Mining and Technology,Xuzhou 221008,China,2.Xuhai College
Abstract:The influence of boiler feed temperature change on thermo-Economics in coal steam-electric plant was researched.The energy-loss analysis model was established in consideration of the boiler efficiency when the feed temperature deviated from the targe.The model is used to real-time calculate the energy-loss for operation parameters of 300 MW unit and the calculation can satisfy the requirements.
Keywords:oal steam-electric plant  feed temperature  energy-loss analysis  energy-saving  