摘    要:简要介绍了地铁消防水系统的组成及设置,着重对地铁地下车站消火栓系统的调试方法进行了阐述,包括水源测试,消防水泵的调试,消火栓系统联动调试等,指出消火栓系统应重复多次调试,使其处于准工作状态,以保障火灾时能及时投入运行。

关 键 词:地铁车站  消火栓系统  调试方法

Study on fire hydrant system debugging method of underground subway station
LIU Chang-qing.Study on fire hydrant system debugging method of underground subway station[J].Shanxi Architecture,2010,36(34):186-187.
Authors:LIU Chang-qing
Affiliation:LIU Chang-qing
Abstract:This article briefly introduces components and setup of subway fire fighting unit, focuses on expounding fire hydrant system debugging method of underground subway station including water resource test, fire fight pump adjustment, and fire hydrant system joint debugging, and points out that: it is necessary to debug fire hydrant system repeatedly and to make it under preparing working condition, so as to ensure timely operation in case of fire.