首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal-hydraulic analysis of the HL-2M divertor using an homogeneous equilibrium model
Authors:Yong LU  Liiun CAI  Yuxiang LIU  Jian LIU  Yinglong YUAN  Guoyao ZHENG  Dequan LIU
Affiliation:Southwestern Institute of Physics, Chengdu 610041, People's Republic of China
Abstract:The heat flux of the HL-2M divertor would reach 10 MWm-2 or more at the local area when the device operates at high parameters.Subcooled boiling could occur at high thermal load,which would be simulated based on the homogeneous equilibrium model.The results show that the current design of the HL-2M divertor could withstand the local heat flux 10 MW m-2 at a plasma pulse duration of 5 s,inlet coolant pressure of 1.5 MPa and flow velocity of 4 m s-1.The pulse duration that the HL-2M divertor could withstand is closely related to the coolant velocity.In addition,at the time of 2 min after plasma discharge,the flow velocity decreased from 4 m s-1 to 1 m s-1,and the divertor could also be cooled to the initial temperature before the next plasma discharge commences.
Keywords:HL-2M device  divertor  homogeneous equilibrium model  pulse duration
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《等离子体科学和技术》浏览原始摘要信息
点击此处可从《等离子体科学和技术》下载全文