首页 | 本学科首页   官方微博 | 高级检索  
     


Long-pulse power-supply system for EAST neutral-beam injectors
Authors:Zhimin LIU  Caichao JIANG  Juniun PAN  Sheng LIU  Yongjian XU  Shiyong CHEN  Chundong HU  NBI Team
Affiliation:Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China
Abstract:The long-pulse power-supply system equipped for the 4 MW beam-power ion source is comprised of three units at ASIPP (Institute of Plasma Physics,Chinese Academy of Sciences):one for the neutralbeam test stand and two for the EAST neutral-beam injectors (NBI-1 and NBI-2,respectively).Each power supply system consists of two low voltage and high current DC power supplies for plasma generation of the ion source,and two high voltage and high current DC power supplies for the accelerator grid system.The operation range of the NB power supply is about 80 percent of the design value,which is the safe and stable operation range.At the neutral-beam test stand,a hydrogen ion beam with a beam pulse of 150 s,beam power of 1.5 MW and beam energy of 50 keV was achieved during the long-pulse testing experiments.The result shows that the power-supply system meets the requirements of the EAST-NBIs fully and lays a basis for achieving plasma heating.
Keywords:EAST  neutral-beam injector  power supply  long pulse
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《等离子体科学和技术》浏览原始摘要信息
点击此处可从《等离子体科学和技术》下载全文