首页 | 本学科首页   官方微博 | 高级检索  
     


High concentration xylene decomposition and diagnostic analysis by non-thermal plasma in a DBD reactor
Authors:Zehua XIAO  Di XU  Chunjing HAO  Jian QIU  Kefu LIU
Affiliation:Department of Light Sources & Illuminating Engineering, Fudan University, Shanghai 200433, People's Republic of China
Abstract:Dielectric barrier discharge (DBD) is utilized to decompose xylene vapor in mobile gas under normal atmospheric pressure.The plasma is generated by an AC power source with a frequency of 6 kHz.In the experiment,the discharge power on the DBD reactor was calculated by a Lissajous figure,and the specific input energy (SIE) of different discharge voltage or residence time was obtained.The concentrations of xylene,carbon monoxide and carbon dioxide in the gas were analyzed by gas chromatography.The spectra of DBD were diagnosed using a spectrometer.We calculated the conversion rate (CR),mineralization rate (MR) and carbon dioxide selectivity.The relationship between these quantities and the SIE was analyzed.The experimental results show that high concentration xylene can be decomposed mostly by DBD plasma.The CR can reach as high as 90% with the main product of carbon dioxide.
Keywords:dielectric barrier discharge  specific input energy  conversion rate  mineralization rate  carbon dioxide selectivity
本文献已被 CNKI 万方数据 等数据库收录!