首页 | 本学科首页   官方微博 | 高级检索  
     


All-optical hydrogen sensor based on a high alloy content palladium thin film
Affiliation:1. College of NanoScale Science and Engineering, University at Albany-SUNY, Albany, NY 12203, USA;2. MTI-Instruments, 325 Washington Avenue Extension, Albany, NY 12205-5505, USA;1. Hubei Collaborative Innovation Centre for Advanced Organic Chemical Materials, State Key Lab of Ferro & Piezoelectric Materials and Devices of Hubei Province, Faculty of Physics and Electronic Science, Hubei University, Wuhan, 430062, PR China;2. School of Physics and Technology, Wuhan University, Wuhan 430072, PR China;1. Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, QLD 4111, Australia;2. School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
Abstract:Optical reflectance measurements were performed to determine the hydrogen response characteristics of 20 nm thick Pd0.6Au0.4 films. The response time and signal change characteristics were determined as a function of hydrogen concentrations ranging from 0.05% to 4% in a balance of dry CO2 free air. The detection limit was determined to be 0.05%, with a corresponding response time of 130 s, while at 4% hydrogen concentrations the response time was 5 s at ambient temperatures. A linear decrease of both the signal change and response time was measured within an operating temperature range between 25 °C and 100 °C for a 1% hydrogen in air gas mixture. The sensor response dependence of the Pd0.6Au0.4 film with a change in humidity was determined between ambient levels and 95% relative humidity (RH). While the signal change was independent of humidity the response time increased due to water adsorption on the Pd alloy sensing layer. A similar increase in response time was shown for 100 ppm of background CO mixed with 1% hydrogen in nitrogen at room temperature. At an elevated operating temperature of 80 °C, 100 ppm of CO did not affect the sensor response towards 1% hydrogen in a balance of nitrogen. Reliability tests have been performed over a 1-year time period and the sensing specifications have not drifted beyond 2% and 13% of the calibrated signal change and response time, respectively. A response time on the order of seconds and the proven stability of the high alloy content Pd thin film demonstrate the promising attributes of this material for use in an all-optical hydrogen sensor.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号