首页 | 本学科首页   官方微博 | 高级检索  
     

二次多负载绕组电压互感器实际负载下的误差测试与计算
引用本文:胡嘉,孙卫明. 二次多负载绕组电压互感器实际负载下的误差测试与计算[J]. 广东电力, 2000, 13(4): 21-24
作者姓名:胡嘉  孙卫明
作者单位:广东省电力试验研究所,广东,广州,510600
摘    要:分析了二次侧具有两个或以上负载绕组电压互感器的误差,推导出电压互感器带实际负载运行时,计量绕组的误差计算公式,并根据误差公式给出了实际负载误差的测试与计算方法。实际测试结果验证了该方法的正确性。

关 键 词:误差测试 误差计算 电压互感器 负载绕组

Measurement and calculation of actual burden error of potential transformer with multiple secondary load windings
HU Jia,Sun Wei-ming. Measurement and calculation of actual burden error of potential transformer with multiple secondary load windings[J]. Guangdong Electric Power, 2000, 13(4): 21-24
Authors:HU Jia  Sun Wei-ming
Abstract:The error of potential transformer (PT) with two and above secondary load windings is dealt with in this paper. The error computing formulas for the measuring winding of practically loaded PT are derived, based on which the measurement and calculation means for actual burden error are presented. Results of actual measurement show the validity of the proposed method.
Keywords:error measurement  error calculation  actual burden  PT  