摘    要:介绍了Cu-H2O体系内铜发生腐蚀的条件,阐述了传统内冷水处理技术的局限性,提出了内冷水微碱化技术,经实际应用取得了预期效果。

关 键 词:  腐蚀  内冷水  微碱化
文章编号:1008-4371(2005)03-0015-04

Technology and Application of Inside Cooling Water Micro-basification Treatment for Generators of Power Plant
WU Chun-an. Technology and Application of Inside Cooling Water Micro-basification Treatment for Generators of Power Plant[J]. Wisco Technology, 2005, 43(3): 15-18
Authors:WU Chun-an
Abstract:The environmental conditions essential to the occurrence of corrosion in Cu-H 2O system are introduced and limitation of the traditional electric generator cooling water treatment technology described and the micro-basification treatment technology for the electric generator cooling water put forward.The expected results have been achieved in the application.