首页 | 本学科首页   官方微博 | 高级检索  
     

计算机射线照相(CR)技术参数对灵敏度的影响
引用本文:王军,强天鹏. 计算机射线照相(CR)技术参数对灵敏度的影响[J]. 无损检测, 2011, 0(10): 50-52
作者姓名:王军  强天鹏
作者单位:江苏省特种设备安全监督检验研究院;
摘    要:就目前业界普遍关注的计算机射线照相(CR)中各参数对检测灵敏度的影响问题进行了分析。试验验证了X射线管电压、曝光量、不同成像板型号和扫描参数对像质计灵敏度的影响规律。最后提出了CR技术应用中需要注意的问题。

关 键 词:计算机射线照相(CR)  系统参数  灵敏度

The Effec of Technical Parameters for the Sensitivity of Computed Radiographic Testing
WANG Jun,QIANG Tian-Peng. The Effec of Technical Parameters for the Sensitivity of Computed Radiographic Testing[J]. Nondestructive Testing, 2011, 0(10): 50-52
Authors:WANG Jun  QIANG Tian-Peng
Affiliation:WANG Jun,QIANG Tian-Peng (Jiangsu Province Special Equipment Safety Supervision Inspection Institute,Nanjing 210003,China)
Abstract:Computed radiography is a research hot in present NDT field.The effect of various parameters on the sensitivity was analyzed.Experiments were carried out to verify the effect of parameters on image quality,such as X-ray tube voltage,exposure,imaging plates type and scanning parameters.At last the problems needed for special concerning were concluded for CR technology.
Keywords:Computed radiographic testing  System parameters  Sensitivity  
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号