首页 | 本学科首页   官方微博 | 高级检索  
     


Natural radioactivity levels of granites used in Turkey
Authors:Cetin E  Altinsoy N  Orgün Y
Affiliation:Istanbul Technical University (ITU), Institute of Energy, Ayazaga Kampusu, 34469 Istanbul, Turkey. cetine@itu.edu.tr
Abstract:Thirty granite samples commonly used in Turkey were surveyed for natural radioactivity. Concentrations of natural radionuclides in all samples were determined by gamma-ray spectroscopy with hyper-pure germanium detector. The activity concentrations measured for (226)Ra and (232)Th ranged from 0.7±0.1 to 186±1 Bq kg(-1), and from 0.5±0.1 to 249±2 Bq kg(-1), respectively. The activity concentrations obtained for (40)K varied from minimum detectable activity (0.4 Bq kg(-1)) to 1935±11 Bq kg(-1). The radium equivalent activity (Ra(eq)), the absorbed dose rate (D), the external hazard index (H(ex)) and the annual effective dose equivalent were also calculated and compared with the international recommended values. Granite samples were also analysed mineralogically. It was observed that the presence of large amount orthoclase and radiogenic accessory minerals are the sources of high activity concentration levels.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号