Characterization of internal thermohydraulic flow and heat transfer improvement in a three-dimensional circular corrugated tube surfaces based on numerical simulation and design of experiment
Authors:Ahmed Ramadhan Al-Obaidi
Affiliation:Department of Mechanical Engineering, Faculty of Engineering, Mustansiriyah University, Baghdad, Iraq
Abstract:To meet the requirements of development in heat exchangers design, the effect of different tubes geometrical parameters on its flow field analysis and thermal heat transfer performance are investigated in the current research work. The hydraulic thermal fluid coupling with computational simulations is applied. The numerical results are solving used flow transport and heat transfer equations, then these results are validated with available experimental data. The behavior of hydraulic and thermal flow in the corrugated tube is discussed with different geometrical parameters' position and shape. Turbulent flow in the tube is calculated in three-dimensional numerical simulations with optimization of a multiobjective algorithm are analyzed. The influences of various design parameters, for instance, the number of corrugated rings around the tube, distance between each corrugated ring, the diameter of the ring, and pitch of ring are investigated firstly in the flow field and then optimized by using the design of experiment (DOE). The influence of flow structural modifications such as static pressure, dynamic pressure, and pressure drop is taken into consideration as analyzed performance parameters. The DOE method is investigated based on implements and variances the L16 orthogonal arrays are chosen as the experimental strategy. Furthermore, the optimization results found that the maximum value of pressure difference was for corrugated diameter. The numerical method using DOE has enhanced heat transfer rate as compared to the smooth pipe. Moreover, the minimum Tout is for Case 11 (296.49°C) and the maximum Tout is for (303.10°C) hence the value of Nu number for both cases is 32.9 and 42, respectively. That means using this type of passive device can improve the heat transfer in the pipe. The outcomes illustrate that the performance evaluation factor (PEF) ratio of the corrugated pipe with different geometrical configurations is changed and increased as the corrugated pipe geometrically changed and the value of PEF is more than 1.3.
Keywords:corrugated tube  DOE method  heat transfer improvement  internal flow  pressure drop
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号