摘    要:介绍了风冷型机房专用空调存在的问题,通过水与空气的比热对比,提出将风冷冷凝器改为水冷冷凝器的改造方案,以及改造配套的土建、电气系统规划设计,并对改造进行了经济性分析。

关 键 词:数据机房  闭式冷却塔  节能改造  专用空调

Application of closed cooling tower in the air conditioning system in the data center
Gong Yunxuan , Lin Chaofeng.Application of closed cooling tower in the air conditioning system in the data center[J].Refrigeration and Air-conditioning,2013(8):23-24.
Authors:Gong Yunxuan  Lin Chaofeng
Affiliation:Gong Yunxuanl) Lin Chaofeng2) 1)(Yantai Ebara Air Condatitionging Equipment Co.,Ltd.) 2)(Henan Huitian-tongchuang Environmental Control Technology Co., Ltd.)
Abstract:Focusing on the problem consist in air cooling type center.By compareing the specific heat of water and air, we put forward the scheme that retrofit air-cooled condenser to water-cooled condenser,what including transform supporting building ,design of electrical system . At length economic analysis of the transformation aslo was made in this thesis.