摘    要:用电渗析技术研究了从印刷线路板废水中精制回收Cu2+的效能。试验结果表明,电渗析能有效富集线路板废水中的Cu2+。当电压为15 V,进水Cu2+、CODCr的质量浓度分别为257、507 mg/L时,Cu2+的富集倍数为2.29,淡室出水的Cu2+质量浓度为0.9 mg/L,Cu2+的去除率达99%,对CODCr的去除率达到43%。但电渗析连续运行结果表明,离子交换膜发生膜污染,产生浓差极化,影响Cu2+的富集,使用的膜还有待改进。

关 键 词:电渗析  印刷线路板废水  富集  铜离子  膜污染

Treatment of PCB wastewater by electrodialysis
XIAO Ya-juan,LV Xi-wu,LI Jin-rong,MA Su-mei.Treatment of PCB wastewater by electrodialysis[J].Industrial Water & Wastewater,2010,41(6).
Authors:XIAO Ya-juan  LV Xi-wu  LI Jin-rong  MA Su-mei
Abstract:The efficiency of electrodialysis technology reclaiming Cu2+ from PCB wastewater was studied.The results of the test showed that,electrodialysis could enrich Cu2+ from PCB wastewater effectively,When the voltage was 15 V,the mass concentration of Cu2+ and CODCr in influent water were 257 and 507 mg/L respective-ly,the concentration factor was 2.29,the mass concentration of Cu2+ in effluent water was 0.9 mg/L,the removal rate of Cu2+ and CODCr reached 99% and 43% respectively.However,the results of the continuous operation of electrodialysis indicated that,the phenomenon of ion-exchange membrane fouling and concentration polarization happened,which affected the enrichment of Cu2+,therefore,the membrane should be improved.
Keywords:electrodialysis  PCB wastewater  enrichment  Cu2+  membrane fouling