摘    要:分析了无功功率产生的原因及中压 ( 6kV)TSC动态无功功率补偿装置的设计原理。安钢高线应用该装置 ,功率因数提高到 0 .98以上 ,谐波得到有效治理

关 键 词:TSC动态无功功率补偿  谐波
文章编号:1003-0514(2003)02-0012-03
修稿时间:2003-03-03

Medium voltage(6kV)TSC dynamic var compensation applied in the high speed wire rod mill in Anyang Steel
XU Hui,DING Jing-qiang,DU Zhen-ning,YE Hui-min. Medium voltage(6kV)TSC dynamic var compensation applied in the high speed wire rod mill in Anyang Steel[J]. Metallurgical Standardization & Quality, 2003, 41(2): 12-14
Authors:XU Hui  DING Jing-qiang  DU Zhen-ning  YE Hui-min
Abstract:The paper analyzed the reason which caused the reactive power and control theory of the installation of medium voltage(6kV)TSC dynamic Var compensation,The Dvc unit was applied to the high speed wire rod mill in Anyang Steel power factor increased over 0.98,the resonance got to be managed efficiently.