首页 | 本学科首页   官方微博 | 高级检索  
     

曝气生物滤池处理炼油厂汽提废水中试
引用本文:钟华文,廖艳,张钧正,何东升.曝气生物滤池处理炼油厂汽提废水中试[J].石油与天然气化工,2003,32(4):252-253256.
作者姓名:钟华文  廖艳  张钧正  何东升
作者单位:1. 茂名学院环境工程系
2. 茂名石油化工公司
摘    要:炼油厂汽提废水含较高的酚和COD,会对污水处理场产生冲击。采用曝气生物滤池法对其进行处理,取得了满意的结果。当水力停留时间为2.0h,处理后出水的酚和COD平均浓度分别为8.5mg/l和140mg/l,平均降解率分别大于90%和70%,完全可以消除它们对污水处理场的冲击。

关 键 词:曝气生物滤池  废水处理  炼油厂  汽提废水  中试    净化装置

Pilot - Plant Test of Treatment Wastewater from Stripping Tower with Biological Aeration Filter
Zhong Huawen,Liao Yan,Zhang Junzheng,et al.Pilot - Plant Test of Treatment Wastewater from Stripping Tower with Biological Aeration Filter[J].Chemical Engineering of Oil and Gas,2003,32(4):252-253256.
Authors:Zhong Huawen  Liao Yan  Zhang Junzheng  
Abstract:Wastewater produced from stripping tower, containing high strength phenol and COD, can bump against wastewater treatment facility. The satisfactory results have been obtained with biological aeration filter: Under the hydraulic retention time of 2. Oh, th
Keywords:pilot-plant  phenol  stripping tower's wastewater  biological aeration filter  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《石油与天然气化工》浏览原始摘要信息
点击此处可从《石油与天然气化工》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏