聚丙烯装置丙烯洗涤塔丙烯排料线开裂原因分析
引用本文:陈勇.聚丙烯装置丙烯洗涤塔丙烯排料线开裂原因分析[J].全面腐蚀控制,2011(8):22-24,30.
作者姓名:陈勇
作者单位:天津石化装备研究院;
摘    要:丙烯排料线与蒸汽伴热夹套管焊接处发生开裂,对失效试件进行宏观检验、扫描电镜、腐蚀产物能谱分析、金相检验等检验检测,分析结果得出排料线为氯化物应力腐蚀开裂的结论,并提出了防护措施。

关 键 词:应力腐蚀  裂纹  焊接接头

Analysis on Cracking Cause of Propylene Discharging Line of PP Unit Propylene Scrubber
CHEN Yong.Analysis on Cracking Cause of Propylene Discharging Line of PP Unit Propylene Scrubber[J].Total Corrosion Control,2011(8):22-24,30.
Authors:CHEN Yong
Affiliation:CHEN Yong(Tianjin petrochemical equipment and instrument research institute,tianjin 300271,China)
Abstract:welding joint of the propylene discharging line and steam heating clip casing had cracked,various inspection and detection had applied on workpiece in failure,such as Macroscopic,SEM,EDS analysis of corrosion products,etallographic examination Etc.,the results obtain discharging line Cracking due to ClSCC,then puts forward the measures of protection.
Keywords:stress corrosion  crack  welding joint  