首页 | 本学科首页   官方微博 | 高级检索  
     


Robustness of an uncertainty and sensitivity analysis of early exposure results with the MACCS reactor accident consequence model
Authors:J C Helton  J D Johnson  M D McKay  A W Shiver  J L Sprung
Abstract:Uncertainty and sensitivity analysis techniques based on Latin hypercube sampling, partial correlation analysis and stepwise regression analysis were used in an investigation with the MACCS model of the early health effects associated with a severe accident at a nuclear power station. The following results were obtained in tests to check the robustness of the analysis techniques: two independent Latin hypercube samples produced similar uncertainty and sensitivity analysis results; setting important variables to best-estimate values produced substantial reductions in uncertainty, while setting the less important variables to best-estimate values had little effect on uncertainty; similar sensitivity analysis results were obtained when the original uniform and loguniform distributions assigned to the 34 imprecisely known input variables were changed to left-triangular distributions and then to right-triangular distributions; and analyses with rank-transformed and logarithmically-transformed data produced similar results and substantially outperformed analyses with raw (i.e., untransformed) data.
Keywords:
本文献已被 ScienceDirect 等数据库收录!