芳烃抽提装置回收塔重沸器管束失效原因
引用本文:翟新亭.芳烃抽提装置回收塔重沸器管束失效原因[J].石油化工腐蚀与防护,2005,22(4):48-50.
作者姓名:翟新亭
作者单位:中国石油化工股份有限公司广州分公司,广东,广州,510726
摘    要:通过对芳烃抽提回收塔重沸器管束的腐蚀分析,指出抽提溶剂环丁砜在高温下分解出SO2、形成酸液以及汽化沸腾对碳钢管束造成了冲刷腐蚀。从优化操作,设备结构及选材方面提出合理解决方案。

关 键 词:重沸器  管束  环丁砜  腐蚀
文章编号:1007-015X(2005)04-0048-03
修稿时间:2005年5月11日

Corrosion Failure of Reboiler Tubes of Recovery Column in Aromatic Extraction Unit
Zhai Xinting.Corrosion Failure of Reboiler Tubes of Recovery Column in Aromatic Extraction Unit[J].Petrochemical Corrosion and Protection,2005,22(4):48-50.
Authors:Zhai Xinting
Abstract:The analysis of the reboiler tubes corrosion of the recovery column in aromatic extraction unit concludes that the failure is the result of erosion corrosion of the carbon steel tubes caused by SO2 from the pyrolysis of extraction solvent sulfolane at higher temperatures, formation of acidic liquid and evaporation boiling. The solutions are recommended in respect of operation optimization, equipment construction and material selection.
Keywords:reboiler  tubes  sulfolane  corrosion