首页 | 本学科首页   官方微博 | 高级检索  
     

铂热电阻的接线造成温度失真现象的研究
引用本文:王雷,胡亚非,杨柱. 铂热电阻的接线造成温度失真现象的研究[J]. 煤炭工程, 2005, 0(9): 69-71
作者姓名:王雷  胡亚非  杨柱
作者单位:中国矿业大学,机电学院,江苏,徐州,221008;中国矿业大学,机电学院,江苏,徐州,221008;中国矿业大学,机电学院,江苏,徐州,221008
摘    要:项目推广中发现很多矿井主通风机的监测温度经常出现不同程度的虚高现象,分析其原因是测温线路的接线引起了较大的温度误差。文章对测温线路进行了理论分析,并通过实验得出导线电阻的大小对温度影响的关系。

关 键 词:PT100  铂热电阻  偏差  线制
文章编号:1671-0959(2005)09-0069-03
收稿时间:2005-02-28
修稿时间:2005-02-28

Research on temperature distortion phenomenon caused by connection of platinum heat resistance
WANG Lei,HU Ya-fei,YANG Zhu. Research on temperature distortion phenomenon caused by connection of platinum heat resistance[J]. Coal Engineering, 2005, 0(9): 69-71
Authors:WANG Lei  HU Ya-fei  YANG Zhu
Abstract:In the application program, it was found that the monitored and measured temperatures of the mine main ventilators in many coal mines ware higher than the actual temperature. The research of the cause showed that the connection of the temperature measuring lines cased the temperature tolerance. After the theoretical analysis of the temperature measuring lines, the test results showed that the resistances of the conducted line have the relationship to the influence of the temperature.
Keywords:PT100   platinum heat resistance   tolerance   line system
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏