工业供热热电联产机组蓄热和放热阶段双向调峰方案研究
引用本文:尉清源,郑莆燕,朱群志,邹思宇,白天宇,程云瑞,封康.工业供热热电联产机组蓄热和放热阶段双向调峰方案研究[J].上海电力学院学报,2022,38(6):594-600.
作者姓名:尉清源  郑莆燕  朱群志  邹思宇  白天宇  程云瑞  封康
作者单位:上海电力大学 能源与机械工程学院
基金项目:上海市科学技术委员会项目(20dz1205208)。
摘    要:以某单级工业供热的热电联产机组为研究对象,在系统中引入蓄热装置并与旁路系统结合,提出了在蓄热和放热阶段均可以调峰的旁路-蓄热调峰方案,以较少的蓄热介质实现了连续长时间调峰。采用 EBSILON 软件搭建机组分析模型,对机组的原调峰方案、抽汽蓄热调峰方案、旁路-蓄热调峰方案进行了对比和分析。结果表明,旁路-蓄热调峰方案的调峰范围最大,降负荷调峰深度最深可达127.5 MW;一个蓄放热周期内旁路-蓄热调峰方案的热效率最高,运行收益最大。

关 键 词:热电联产机组  蓄放热  双向调峰
收稿时间:2022/4/2 0:00:00

Research on Two-Way Peak Regulation Scheme of Heat Storage and Discharge for Industrial Heating Units
WEI Qingyuan,ZHENG Puyan,ZHU Qunzhi,ZOU Siyu,BAI Tianyu,CHENG Yunrui,FENG Kang.Research on Two-Way Peak Regulation Scheme of Heat Storage and Discharge for Industrial Heating Units[J].Journal of Shanghai University of Electric Power,2022,38(6):594-600.
Authors:WEI Qingyuan  ZHENG Puyan  ZHU Qunzhi  ZOU Siyu  BAI Tianyu  CHENG Yunrui  FENG Kang
Affiliation:School of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 200120, China
Abstract:This paper takes a single-stage industrial heating cogeneration unit as the research object,introduces a heat storage device into the system and combines it with the bypass system,and proposes a bypass-heat storage regulation that can adjust peaks in both the heat storage and heat release stages.This scheme can achieve continuous long-term peak regulation with less heat storage medium.This paper uses Ebsilon software to build the unit analysis model,and analyzes the original peak shaving scheme,the extraction steam heat storage peak shaving scheme,and the bypass-heat storage peak shaving scheme.The results show that the peak shaving range of the bypass-thermal storage peak regulation scheme is the largest,and the peak load reduction depth can reach 127.5 MW; the thermal efficiency of the bypass-thermal storage peak regulation scheme is the highest in one storage and discharge cycle,and the operation benefit is the largest.
Keywords:combined heat and power unit  heat storage and discharge  steam bypass peak shaving