首页 | 本学科首页   官方微博 | 高级检索  
     

氧化塔内置盘管式不锈钢换热器的失效分析
引用本文:董雷云,刘长军,潘缉悌.氧化塔内置盘管式不锈钢换热器的失效分析[J].化工机械,2002,29(3):164-166.
作者姓名:董雷云  刘长军  潘缉悌
作者单位:华东理工大学
摘    要:利用光学显微镜、扫描电镜、电子能谱等测试手段 ,从材料成分、微观组织、断口形貌以及腐蚀产物成分等角度 ,分析了氧化塔内置盘管式不锈钢换热器开裂失效的原因。结果表明 ,该不锈钢换热器失效的原因是氯离子引起的应力腐蚀开裂所致

关 键 词:不锈钢  换热器  失效分析
文章编号:0254-6094(2002)03-0164-03

Failure Analysis of Built-In Coil Heat Exchangers of Stainless Steel in Oxidation Towers
DONG Leiyun,LIU Changjun,PAN Jiti.Failure Analysis of Built-In Coil Heat Exchangers of Stainless Steel in Oxidation Towers[J].Chemical Engineering & Machinery,2002,29(3):164-166.
Authors:DONG Leiyun  LIU Changjun  PAN Jiti
Abstract:The failure analysis was made of the cracking of the built in coil heat exchanger of stainless steel in an oxidation tower in material composition,micro structure fracture appearance,and compositions of corrosion products by using optical microscope,SEM,electronic energy spectrum. The result shows that the failure cause of the heat exchanger was SCC induced by Cl.
Keywords:Stainless Steel  Heat Exchanger  Failure Analysis  