首页 | 本学科首页   官方微博 | 高级检索  
     

电机定子绕组湿裂引起电机匝间的分析
引用本文:隋景鹏,苏宝龙. 电机定子绕组湿裂引起电机匝间的分析[J]. 防爆电机, 2009, 44(1): 46-47
作者姓名:隋景鹏  苏宝龙
作者单位:海军驻哈地配军事代表室,黑龙江哈尔滨,150046  
摘    要:电机定子绕组匝间是指电机同一相的线圈绕组匝之间的绝缘,由于绝缘结构和绝缘材料不同以及在绕线、嵌线、刮线接头、端部整形、绝缘浸漆、装配等工序中因操作工艺不当而引起不同程度的绝缘损伤并在绕组通电后产生短路的现象。绕组匝间短路将导致定子电流急剧增大,进而烧毁电机绕组。因此必须高度重视定子绕组匝间问题,及时查找原因,采取预防措施,避免事故发生。

关 键 词:定子绕组  电磁线漆膜  湿裂  匝间短路

Turn-to-turn Fault Caused by Humidity Crack of Motor Stator Windings
Sui Jingpeng , Su Baolong. Turn-to-turn Fault Caused by Humidity Crack of Motor Stator Windings[J]. Explosion-proof Electric Machine, 2009, 44(1): 46-47
Authors:Sui Jingpeng    Su Baolong
Affiliation:Sui Jingpeng , Su Baolong
Abstract:Turn-to-turn fault of motor stator is caused by different insulation construction and material between turn and turn of coil winding in same phase, and insulation damage in variant degrees from unsuitable operation process in winding wire, embedding wire, scrapping wire joint, reforming end winding, impregnating varnish and installation,etc. Turn-to-turn short circuit of stator winding can result in sudden increase of stator current, thus burn up the windings. So attaching great importance to turn-to-turn f...
Keywords:Stator winding  varnish film of magnetic wire  humidity crack  turn-to-turn short circuit  
本文献已被 CNKI 维普 万方数据 等数据库收录!