UPLC-MS/MS测定人血浆中罗红霉素的浓度及在药代动力学中的应用
引用本文:胡岚岚,汤建林,周世文,徐颖,张玥. UPLC-MS/MS测定人血浆中罗红霉素的浓度及在药代动力学中的应用[J]. 中国测试技术, 2013, 0(6): 60-63
作者姓名:胡岚岚  汤建林  周世文  徐颖  张玥
作者单位:第三军医大学新桥医院临床药理基地,重庆400037
摘    要:建立一种快速、准确测定人血浆中罗红霉素浓度的UPLC-MS/MS分析方法。以克拉霉素为内标,0.2mL含药血浆经碱化、乙酸乙酯萃取后进样分析;色谱柱为Acquity UPLC BEH C18(2.1mm×50mm×1.7μm),流动相组成为乙腈∶0.01%醋酸铵=30∶70,梯度洗脱方式,乙腈比例在4 min内从30%变为70%,流速0.3 mL/min,柱温为35℃,进样量3μL。质谱条件:气动辅助电喷雾离子化(ESI)源;正离子检测(MRM)模式,罗红霉素质荷比为(m/z 837.53→m/z 158.15)和克拉霉素质荷比为(m/z 748.48→m/z 590.30)。罗红霉素在0.05~25.6μg/mL的浓度范围内呈线性,定量下限为0.05μg/mL,基质效应影响小,日内变异系数小于10.3%,日间变异系数小于9.4%,相对回收率在97.5%~106.4%之间。该方法准确、快速、灵敏,可用于微量血浆的罗红霉素药物浓度监测、人体内药代动力学及生物等效性研究。

关 键 词:罗红霉素  UPLC-MS  MS  药代动力学  血浆

Quantification of roxithromycin in human plasma by UPLC-MS/MS and its application in a pharmacokinetic study
HU Lan-lan,TANG Jian-lin,ZHOU Shi-wen,XU Ying,ZHANG. Quantification of roxithromycin in human plasma by UPLC-MS/MS and its application in a pharmacokinetic study[J]. China Measurement Technology, 2013, 0(6): 60-63
Authors:HU Lan-lan  TANG Jian-lin  ZHOU Shi-wen  XU Ying  ZHANG
Affiliation:Yue (Base for Drug Clinical Trial,Xinqiao Hospital,Third Military Medical University, Chongqing 400037, China)
Abstract:To establish a rapid and accurate method for quantification of roxithromycin in human plasma with UPLC-MS/MS, human plasma sample was alkalized by sodium carbonate, extracted with ethyl acetate, the roxithromycin and internal standard clarithromycine were separated on an acquity UPLC BEH C18 column(2.1 mm×50 mm× 1.7 μm) using gradient elution with acetonitrile(mobile phase A) and 0.01% ammonium acetate(mobile phase B) with a flow rate of 0.3mL/min and a total runtime of 4.0 min. Mass spectrometry: The analytes were detected by the electronicspryionization(ESI),selected multiple reaction monitoring(MRM) using the precursor to product ion combinations of m/z 837.53 →158.15 and m/z 748.48 →590.30 was performed to detect roxithromycin and the internal standard respectively. The method was linear over the concentration range of 0.05-25.6 μg/mL. The lower limit of quantification was 0.05 μg/mL. Intra-day inaccuracy was within 10.3% and inter-day was less than 9.4%. Matrix effects were minor. The recovery of the method was between 97.5% and 106.4%. The validated method was developed for quantification of roxithromycin in small volumes of plasma. The method can be used for therapeutic drug monitoring and the study of pharmacokinetics and bioavailability of roxithromycin.
Keywords:roxithromycin  UPLC-MS/MS  pharmacokinetics  plasma